All load cells are not alike. Our legacy load cell line provides an attention to detail beneath the surface that separates a Hardy Load Sensor from a common load cell. Attention to detail saves you time and money.
Excitation (VDC) . . . . . . . . . . . . . . . . . . . 10 Nom., Max. 15 Rated Output (mV/V) . . . . . . . . . . . . . . . . 3 ± 0.3 Zero Balance (Max.) . . . . . . . . . . . . . . . . . 1% of Full Scale Combined Error . . . . . . . . . . . . . . . . . . . . 0.03% of Full Scale Non-Repeatability . . . . . . . . . . . . . . . . . . .0.01% of Full Scale Creep (Max.) . . . . . . . . . . . . . . . . . . . . . .0.03% of Load in 20 Minutes Temperature Sensitivity (Max.) Output . . . . . . . . . . . . . . . . . . . . . .. . . . .0.0008% of load /EF Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.0015% of Full Scale/EF Resistance EXC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 ohms ± 30 ohms SIG . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 ohms ± 3.5 ohms Operating Temperature . . . . . . . . . . . . . . .-65EF to +200EF or -54EC to +93EC Compensated Temperature . . . . . . . . . . . . . 0EF to 150EF or -18EC to +65EC Safe Overload . . . . . . . . . . . . . . . . . . . . . .150% of Full Scale Safe Side Load . . . . . . . . . . . . . . . . . . . . . 100% of Full Scale
Maximum Capacity (Emax ) 200 / 500 / 1000 / 2500 / 5000 lb Rated Output (=RO) mV/V 2 ± 0.1% Accuracy class according to OIML R60 C3 Maximum number of verification intervals (nmax) 3000 Maximum load cell verification interval (vmin) Emax/11500 Combined error %*RO ≤ ± 0.0200 Non-linearity %*RO ≤ ± 0.0166 Hysteresis %*RO ≤ ± 0.0166 Creep error (30 minutes) / DR %*RO ≤ ± 0.0166 Temperature effect on minimum dead load output (TC0) %*RO/10°C ≤ ± 0.0122 Temperature effect on sensitivity (TCR0) %*RO/10°C ≤ ± 0.0100 Excitation voltage V 5… 15 Zero balance %*RO ≤ ± 5 Input resistance (RLC) Ω 1100 ± 50 Output resistance (Rout) Ω 1000 ± 2 Insulation resistance MΩ ≥ 5000 Compensated temperature range °C -10… +40 Operating temperature range °C -20… +65(ATEX -20…+60) Safe load limit (Elim) %*Emax 200 Ultimate load %*Emax 300 Safe side load %*Emax 100 Load cell material Stainless steel 17-4 PH (1.4548) Sealing potted Protection according DIN 60 529 IP67 Calibration in mV/V/Ω (A...I classified) % ≤ ± 0.05 (≤ ± 0.005) Weight Kg 1.1- 1.2
Excitation (VDC) :10 Nom., Max. 15 Rated Output (mV/V): 0.3 ± .003 Zero Balance (Max.): 1% of Full Scale Combined Error: 0.03% of Full Scale Non-Repeatability: 0.02% of Full Scale Creep (Max.): 0.03% of Load in 20 Minutes Temperature Sensitivity (Max.) Output: 0002% of load /°F or .00018%/°C Zero :005% of Full Scale/°F or .045%/°C Resistance EXC: 350 ohms ± 3.5 SIG: 350 ohms ± 3.5 Operating Temperature: -65°F to +200°F or -54°C to +93°C Compensated Temperature: 0°F to 150°F or -18°C to +65°C Safe Overload: 150% of Full Scale Safe Side Load: 100% of Full Scale
Excitation (VDC) :10 Nom., Max. 15 Rated Output (mV/V): 3 ± .003 Zero Balance (Max.): 1% of Full Scale Combined Error: 0.03% of Full Scale Non-Repeatability: 0.01% of Full Scale (.02% for Stainless Steel) Creep (Max.): 0.03% of Load in 20 Minutes Temperature Sensitivity (Max.) Output: 0008% of load /°F or .00018%/°C (.002% for Stainless Stee l) Zero :0015% of Full Scale/°F or .005%/°C Resistance EXC: 700 ohms ± 3.5 SIG: 350 ohms ± 3.5 Operating Temperature: -65°F to +200°F or -54°C to +93°C Compensated Temperature: 0°F to 150°F or -18°C to +65 °C Safe Overload: 150% of Full Scale Safe Side Load: 100% of Full Scale
Excitation (VDC) :10 Nom., Max. 15 Rated Output (mV/V): 2 ± .002 Zero Balance (Max.): 1% of Full Scale Combined Error: 0.03% of Full Scale Non-Repeatability: 0.01% of Full Scale Creep (Max.): 0.03% of Load in 20 Minutes Temperature Sensitivity (Max.) Output: 0008% of load /°F or .00018%/°C (.002% for Stainless Stee l) Zero :0015% of Full Scale/°F or .005%/°C Seal: Hermetic Resistance EXC: 440 ohms ± 70 SIG: 350 ohms ± 3.5 Operating Temperature: -65°F to +200°F or -54°C to +93°C Compensated Temperature: 0°F to 150°F or -18°C to +65 °C Safe Overload: 150% of Full Scale Safe Side Load: 100% of Full Scale