HI 3300 Tension Controller

Weighing Instruments

Hardy Legacy Weight Controllers have typically been replaced by newer models that offer outstanding performance and an exceptional value.  Product users may find useful reference material in this section. 

HI 1771WS

HI 1771WS

HI 1771WS

• Power
– +5Vdc +/-5% from the 1771 I/O universal chassis
– 1,000Vdc minimum isolation from backplane logic
circuirtry
• Backplane Current
1.5A (maximum)
• Inputs
– Signal: -0.3mV thru +30.3mV dc
– Sense: +/-5V dc +/-5% (10V dc +/-5% differential)
– C2®, Second Generation Calibration data
• Outputs
– Excitation: 10V dc +/-5% 1.5W (maximum)
– Set point: 2 independent TTL level drive signals
• Common Mode Rejection
100dB at or below 60 Hz (minimum)
• Resolution
Reported: 1:985,000 (for 3mV/V load cell)
1:656,000 (for 2mV/V load cell)
Internal: 1:1,048,576
• Vibration Frequency Rejection
0.25 Hz and above in 5 selectable steps
• I/O Chassis Location
Any single I/O module slot
• Compatible I/O Chassis
1771-A1B, -A2B, -A3B, -A3B1, -A4B, 1771-AM1,
-AM2
• I/O Chassis Keying Positions
Between 24 and 26
Between 32 and 34
• I/O Chassis Addressing Mode
2-slot, 1-slot, or ½-slot (Note: 8-bit I/O image density)
• Weight
1.6 Lbs (0.6kg)
• Environmental Conditions
Operating Temperature: 0 to 60°C (32 to140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
• Relative Humidity
5 to 95% (non-condensing)
• Weighing Modes
Net, Gross, Rate-Of-Change

HI 3300 Tension Controller

HI 3300 Tension Controller

HI 3300 SPECIFICATIONS
• Display
64 x 128 Graphics Display with backlit LCD
• Update Rate
55 times per second
• Averaging
Sliding up to 250 readings in single unit increments
• Resolution
Display 1:985,000 (3mv/v load cells)
Internal 1:1,048,000
• Standard Interfaces
Ethernet: 10/100base T; embedded web server
Infrared (IR): wireless connection to Palm OS PDAs
• Stable Weight Reading
WAVERSAVER® 0.25 Hz minimum
• Calibration Techniques
C2®, Second Generation Calibration (elec-tronic
Traditional calibration with test weights); soft
calibration
• Instrument Local I/O
Five mappable inputs optically isolated
Four mappable outputs 48-240VAC Form A
Third party mappable over DeviceNet®
Dual 4-20 mA output
• Load Sensors
Inputs from strain gage and LVDT load cells
• Power Requirement
108-264VAC, 47-63hz or 12-24 VDC
10 Watts maximum
• Operating Temperature
-10° to 50° C (14° to 122°F)
• Storage Temperature
-20° to 70° C (-4° to 158°F)
• Enclosure
Panel Mount; Swivel Mount
• Dimensions
Panel Mount
- Depth 6.03” (153mm) with rear cap
- Panel Cutout: 8.94”W x 6.63”H

HI 2151/20WC replaced by HI 2151/30WC

HI 2151/20WC

Series V

Series V

Hardy 2160RCPlus Rate Controller

HI 2160RCPlus

The HI 6300 series can be used as a standalone weight processor or as the front-end to a weight-based control system. The instrument reads, conditions, and digitizes load cell and strain gauge signals commonly found in process weighing applications, including inventory management, batching, blending, filling, dispensing, and check weighing.

HI 6300 Series